Gear gap detection

Gear gap detection
Gear gap detection
Gear gap detection
Gear gap detection
Gear gap detection
Gear gap detection

Gear gap detection

Industry pain points and demands

The clearance size of the gear is an important parameter, reasonable clearance will make the gear more smooth and durable, in the practical application of gear, if there is no clearance between the gears, it will lead to mutual extrusion of the gears, temperature rise and other problems, so it is necessary to detect the clearance of the gear.

Contact Now

Advantages & characteristics

01 With SR9040, the Z-axis dynamic repeatability accuracy is up to 0.02mm and X-axis resolution is 3μm
02 Detection speed up to 50mm/s, can be stable identification
03 The gap exceeding 0.04mm can be stably detected

Effect display

Camera Selection

Model number
SR9040
Reference distance (CD)40mm
Measuring rangeZ-axis height (FS)The 6.6 mm
X-axis widthProximal endThe 16.2 mm
Reference distance17mm
Distal end18mm
Light sourceLight source wavelength405nm
Laser class2M
Laser output power10mW
Repetition accuracyZ-axis (height)0.1 mu m
X-axis (width)0.6 mu m
linearityZ-axis (height)±0.05% FS
Contour data intervalX-axis (width)3 microns
X-axis contour points6400
Scanning speed (Hz)1500 ~ 13000
I/O interface8 programmable input interfaces, 8 programmable output interfaces
Encoder interfaceOne single end, one difference encoder
Input/outputOne RS232 interface and one 100Base-TX/1000Base-T Ethernet interface
Operating temperature0 to 45°C
Storage temperature-20 to 70°C
Working humidity35% to 85% no condensation
ESD protectionContact discharge 4kV, air discharge 8kV, in accordance with IEC61000-4-2 standard
EFT protection

Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, compliant with

IEC61000-4-4 standard

Impact50Gs/3ms per axis, in accordance with IEC 68-2-27 Ea
Vibration10Gs (10-500Hz), compliant with IEC 68-2-6 Fc
IP levelIP67
Size (mm)179 x 69.5 x 130
Data cable (wiring) modelSCB-HCAM-HB1-3m、SCB-HCAM-HB1-10m
Weight1920g