Medical Glass Bottle Thickness Detection with SinceVision Spectral Confocal Displacement Sensor
Industry pain points and demands
Glass bottles are widely used in the pharmaceutical industry for their stability, but ensuring consistent thickness is critical for safety and quality. Variations in thickness can compromise the integrity of the packaging, risking drug safety.
The SinceVision SCI04025 Spectral Confocal Displacement Sensor provides precise and real-time detection of glass bottle thickness. Its advanced point spectroscopy technology ensures reliable measurement, even with transparent materials, enabling immediate elimination of defective bottles.
Physical Picture or Imaging Effect Picture
SinceVision Solution: SCI04025 Spectral Confocal Displacement Sensor
01High Precision & Wide Angle Capability: Delivers unmatched accuracy with a 12μm spot size and handles angles up to ±25° for reliable detection on various bottle shapes.
02Real-Time & Stable Detection: Identifies thickness inconsistencies instantly with a sampling frequency of up to 33kHz, ensuring accuracy for fast-moving objects and high-frequency vibrations.
03Durable Performance: Engineered to meet the stringent demands of pharmaceutical packaging processes, ensuring efficiency and consistent quality.
Camera Selection
Fixture model | SCI04025 | |
controller | SCI501A/SCI502A/SCI501B/SCI502B | |
Fixture Model | SCI-01 | |
Spot size | 12μm | 25.2μm |
Measuring range | 4mm | |
Working distance | 16mm | |
Axial resolution | 0.006μm | |
straightness | ±0.8μm | |
Angle characteristic | ±25° | |
Minimum measurable thickness of transparent object | 130μm | |
diameter | 30mm | |
length | 114mm | |
weight | 95g |